The IU50 Ultrasonic Level Measurement is mounted on top of the vessel. Under the control of the electronic unit, the probe emits ultrasonic wave pulse to measured medium. The sound wave is reflected by the surface of medium, a part of reflection echo is received by the probe and converted into electrical signal. From the emission of the ultrasonic wave to the new reception,the time is direct proportion to the distance from the probe to the measured medium. The electronic unit detects the time and calculates out the easured distance according to the known sound velocity. Use subtraction to obtain the value of medium position. It is widely used in open pipe, oil tank, pump station, water tower, dam, open channel, difference between levels etc.
1) LCD display,
2) High-precision real-time performance, high sampling frequency, low frenquency, low power consumption
3) 2 relay outputs, 220VAC/3A;
4) Can be in the chemical industry, metallurgy industry, oil and electricity automatic field
Ultrasonic Part Parameter |
Functions |
Integrative Type |
Level Range: |
5M, 10M, 15M, 20M,30M, 50M. |
Accuracy: |
0.5%F.S |
Blind Zone: |
0.2-0.6m |
Working Pressure: |
2 Bar (Explore Proof Type is 5 Bar) |
Resolution: |
3mm or 0.1%F.S (Max of them) |
Display: |
English language display:Level measurement, distance measurement, transmission value, ambient temperature, echo state, alarm display, algorithm selection. |
Output: |
0-5V,0-10V,4~20mA/750Ω load resistance (2 wire)
RS485 |
Relay /Alarm Output: |
AC 250V/ 8A; DC 30V/ 5A; |
Power Supply: |
24VDC 120mA
12VDC (available to offer power by motor, battery or solar power and so on.) |
Environment Temperature: |
Meter: -20~+60°C/ Sensor: -20~+80°C |
Explore Proof: |
Ex(ia)ⅡCT6 |
Water Proof: |
Standard Type: IP66 |
Cable of Sensor: |
Null |
Sensor Installation: |
By level range and model code |
Store Request: |
Temperature: -20~+80°C
Pressure: atmospheric pressure
Humidity: ≤90%RH
Others:Non-corrosive gases (optional corrosion probe) or steam, no vibration. |
|